Example 1
Installation Example
In this installation 2 x loadmaster controllers are used each powering a separate hot water cylinder.
Controller 1 is powering a 200L hot water cylinder using a single series array of 6 x 330-Watt PV panels.
Heater element 4KW
Controller 2 is powering a 150L hot water cylinder using a single series array of 5 x 330 Watt PV panels.
Heater element 4KW
Both controllers have battery backup to avoid the effects of unplanned power outages.
Manual changeover switches have been installed to run hot water cylinders from mains supply during times of very low or no sun.
Unused outputs will be used to divert excess solar to a solar system that the client is planning to install.
Example 2
Installation Example
In this installation 1 x loadmaster controller is used to power 2 x hot water cylinders. One being a 150L with the other being a 200L. The controller is using a single series array of 5 x 375 Watt PV panels.
Heater element 4KW
In this case the loadmaster is part of a solar system and can be switched over to mains manually in periods of no or low sun.